Siemens Siemens.com Siemens diagnostics.com
Search Our Knowledge Base
Physicians Laboratory Professionals Healthcare Administrators Patients
 
Home


Ensures Good Laboratory Practices
"[The Stratus® CS Analyzer] satisfies the requirements specified in IFCC and National Academy of Clinical Biochemistry recommendations for the use of biochemical markers in acute coronary syndromes..."
 
S. Altinier, et al. Clinical Chemistry. 2000.3
   
 
Designed for Acute CareSM Diagnostics  
 

NOW–Electronic System Check maximizes flexibility for liquid QC test frequency

The Stratus® CS System has been designed to be in compliance with laboratory accrediting agencies such as CAP, JCAHO and NCCLS, who allow the use of daily System Check (Electronic QC) to satisfy the routine QC requirement for cardiac markers in lieu of daily assays of liquid controls.*
  Optical Detection System– Continuously monitored and adjusted
  Mechanical Alignments– Sensors and motion control software automatically verify critical alignment parameters
  Fluid Handling System– Continuously monitored and adjusted
  Contamination Prevention– Use of air displacement and disposable pipette tips prevent carryover and reagent cross contamination
  Temperature– The temperature of the thermal chamber and fluorometer are verified to be 37ºC ± 0.2º

"[Automated System Checks] are more sensitive than conventional liquid control materials at detecting instrument malfunction...detect malfunctions before results are compromised...consume no reagents, and require less than six minutes..."
S.L. Frye. 1999.8

Customize your QC Program with Lockouts
If any lockout conditions are violated, the system will not allow patient samples to be processed.

     
  System Check Lockout–System Check must be performed within a period of time you specify (0 to 30 hours)
  Liquid QC Lockout– Liquid QC must be performed within a time you specify (up to 60 days)
  Liquid QC Range Lockout– Liquid QC results must be within a user-specified range

What's more, Connectivity / Remote System Monitoring enables the laboratory to maintain control via LIS interface.


Meeting the Demand for Valuable Information
Because Every Minute Is A Measure Of Myocardium
Simple to Operate, Optimal for All Skill Levels
Ensures Good Laboratory Practices
While Providing Substantial Savings



For more information on Stratus® CS System, click here.

To learn more and/or to schedule a cardiac consultation which includes a personalized economic and workflow analysis, click here.



Acute Care™ Cardiac Troponin I
Acute Care™ Myoglobin
Acute Care™ CK-MB (mass)
Acute Care™ ßhCG
Acute Care™ D-Dimer
Acute Care™ NT-proBNP

Correlation
Connectivity


* Liquid Control solutions should be assayed in conformance with regulations or accreditation requirements and as recommended for troubleshooting.

References

© Siemens Healthcare Diagnostics Inc. 2007-2008 | Corporate Information | Privacy Policy | Terms of Use | Home | What's New | Glossary | Contact Us | Site Map | Site Index